Description
The Weitlaner Retractor with Solid Blades is a self-retaining surgical retractor designed to maintain controlled separation of muscles and soft tissues while providing access to deeper anatomical structures. Its solid-blade configuration and locking mechanism allow the selected opening to be maintained without continuous manual holding during the procedure.
The current Peak Surgicals model is identified as SKU PS-Or_0013 and is manufactured from medical-grade stainless steel. The product is intended for professional use in orthopedic, spinal, neurosurgical, and general surgical procedures where stable tissue retraction is required.
Solid Blade Weitlaner Design
The defining feature of this model is its solid blade configuration. The working blades engage the tissue margins while the instrument is opened to create the required surgical exposure.
Solid blades provide a different working profile from wire-frame or other retractor designs and should be selected according to the tissue being retracted, depth of the operative field, and surgeon preference.
Self-Retaining Retraction Mechanism
The Weitlaner pattern uses a self-retaining scissor-style mechanism. After the blades are positioned and opened, the instrument can maintain the selected degree of separation without requiring an assistant to hold the retractor continuously.
This design is useful during procedures where the surgical team requires sustained access to deeper structures while other instruments are being used within the operative field.
Ratcheted Lock for Adjustable Opening
The current product description identifies a ratcheted locking mechanism that allows the retractor to be opened and secured at the required position. The ratchet provides incremental adjustment of the blade separation according to the surgical exposure required.
Before clinical use, the locking mechanism should be inspected to confirm smooth engagement and release. A retractor with damaged, loose, or unreliable ratchet engagement should be evaluated before use.
Muscle and Soft-Tissue Retraction
The primary function of the Weitlaner Retractor is to maintain muscle and soft-tissue separation during surgery. Stable retraction provides access to deeper anatomical structures while helping maintain an open operative field.
The amount of retraction should be controlled according to the tissue, anatomical location, and surgical technique. Instrument positioning and tension remain the responsibility of the operating surgeon.
Spinal and Laminectomy Applications
The current Peak Surgicals product information specifically references spinal procedures and neurosurgical laminectomy. In these procedures, self-retaining retractors may be used during surgical exposure to maintain separation of soft tissues surrounding the operative area.
The required retractor size, blade configuration, placement, and opening should be selected according to the spinal level, operative approach, tissue depth, and surgeon preference.
Orthopedic and General Surgical Use
In addition to spinal procedures, the current listing identifies orthopedic and general surgery among the applications for this Weitlaner pattern. The instrument can therefore be incorporated into surgical sets where controlled self-retaining soft-tissue exposure is required.
Suitability for an individual procedure should be determined according to anatomical access and the characteristics of the tissue being retracted rather than specialty name alone.
Medical-Grade Stainless Steel Construction
The Weitlaner Retractor with Solid Blades is manufactured from medical-grade stainless steel. The rigid construction supports the mechanical forces involved in tissue retraction and is suitable for reusable professional surgical instrumentation.
The exact stainless-steel alloy grade is not stated on the current product page. Hospitals, distributors, and procurement teams requiring a specific alloy designation or supporting material documentation should confirm those details before ordering.
Reusable and Autoclavable Instrument
The current product description identifies the instrument as compatible with standard sterilization methods including autoclaving. Following use, it should be cleaned, inspected, and reprocessed according to applicable manufacturer instructions and the healthcare facility’s validated procedures.
Particular attention should be given to the solid blades, pivot, ratchet teeth, joints, and other moving surfaces. Before reuse, inspect the instrument for retained debris, corrosion, deformation, restricted movement, blade damage, or unreliable ratchet engagement.
Product Specifications
| Product Name | Weitlaner Retractor with Solid Blades |
| Storefront SKU | PS-Or_0013 |
| Instrument Type | Self-Retaining Surgical Retractor |
| Pattern | Weitlaner |
| Blade Configuration | Solid Blades |
| Mechanism | Self-Retaining Scissor-Style Mechanism |
| Locking System | Ratcheted Lock |
| Primary Function | Muscle and Soft-Tissue Retraction |
| Referenced Applications | Spinal, Laminectomy, Orthopedic and General Surgical Procedures |
| Material | Medical-Grade Stainless Steel |
| Size | Selectable Option – Exact Values to Be Confirmed |
| Reuse | Reusable Surgical Instrument |
For Hospitals, Surgical Departments and Procurement
The Weitlaner Retractor with Solid Blades is relevant for orthopedic hospitals, spine and neurosurgical departments, general operating rooms, trauma services, medical distributors, and procurement teams sourcing reusable self-retaining retractors.
For purchasing and inventory identification, buyers can reference SKU PS-Or_0013, the Weitlaner pattern, solid-blade configuration, ratcheted self-retaining mechanism, and stainless-steel construction. Buyers requiring exact overall length, blade dimensions, blade-tip configuration, or stainless-steel alloy grade should confirm those specifications before ordering because they are not clearly provided in the current accessible listing.
Frequently Asked Questions
What is a Weitlaner Retractor with Solid Blades used for?
It is designed to maintain controlled separation of muscles and soft tissues so deeper anatomical structures remain accessible during surgery.
Is the Weitlaner Retractor self-retaining?
Yes. The current product information identifies a self-retaining scissor-style mechanism with a ratcheted lock that maintains the selected opening.
Can this retractor be used in spine surgery?
Yes. The current Peak Surgicals description specifically references spinal procedures and neurosurgical laminectomy among its applications.
What material is the retractor made from?
The current listing specifies medical-grade stainless-steel construction. The exact alloy grade is not stated.
Can the Weitlaner Retractor be autoclaved?
The current product description identifies the instrument as compatible with standard sterilization methods including autoclaving. Reprocessing should follow the applicable validated protocol.
What is the SKU for this instrument?
The current Peak Surgicals storefront displays PS-Or_0013 as the SKU.